Traffic
UPS Specifications - TRTC-2000N |
|
|
|
|
|
 |
| ELECTRICAL |
| INPUT |
| Voltage
Range, VAC |
90
to 150 programmable
Default 100 to 130 +/- 2VAC |
| Frequency,
Hz |
60
+/- 3 Hz |
| Maximum
Input Current, A |
30
A (Resistive) |
| Inrush
Current |
Load
Dependent |
| Over
current Protection |
Double
pole single throw circuit breaker rated 30 A
for input and output
DC bus 60 A breaker |
| Transient
Suppression |
MOV
transient suppression elements (>150 V) |
| Step
Load Response (50% Load Charge) |
1/2
Cycle Full Recovery (Full resistive load) |
| Short
Circuit Protection |
15
A Circuit Breaker |
| Battery
String Voltage, VDC |
48
(Four 12VDC Batteries) |
| OUTPUT |
| Apparent
Power, VA |
2000VA
(Inverter Mode)
2000VA (Line Mode) |
| Active
Power, W |
1500
(Inverter Mode)
1500 (Line Mode) |
| Power
Factor |
0.75 |
Output
Voltage, VAC
Line and Buck/Boost Mode
Inverter Mode |
120
nominal
100-130 +/- 2 VAC (follows input voltage)
120 VAC +/- 5% |
| Frequency,
Hz |
60
+/- 0.4 Hz |
| Transformer |
Linear
(non-isolated) |
| Output
Waveform |
Sine
Wave |
| Output
Waveform THD |
<3%
(Resistive Load) |
| Load
Crest Factor |
3:1
(Max) |
| Overload
Capacity |
110%
for 3 min. |
| PERFORMANCE |
Transfer
Time
- Controller
- PTS
- TOTAL |
4
to 10 ms
<30 ms
<65 ms |
| Efficiency,
Line Mode |
>95%
(Resistive Load) |
| Efficiency,
Inverter Mode |
>80%
(Resistive Load) |
|
|
| ENVIRONMENTAL |
| Operating
Temp °C |
-37
to +74°C
(See Notes 1 & 2) |
| Storage
Temp °C |
-50
to +75°C |
| Humidity |
<95%
non-condensing |
| Altitude,
ft (m) |
10,000
(3000)
(See Note 2) |
| MECHANICAL |
Dimensions
(WxDxH) inch/mm |
W
17.5/444 - 19/483 w/flange
D 10.5/267
H 5.25/133 - 3 U |
| Weight
(lb/kg) |
46.2/21 |
| Mounting |
19"
(483 mm) rak or shelf mount |
| Input
Connection |
3
Position Terminal Block |
| Output
Connection to Loads |
Two
3 Position Terminal Blocks |
|
Cooling |
Microprocessor
controlled, 12 VDC, 3.6" (92 mm) fan |
| Audible
Noise Level, dBA |
<40 |
| MBS/PTS
Dimensions (WxDxH) inch/mm |
W
17.5/444 - 19/483 w/flange
D 8.5/216
H 3.5/89 - 2U |
| MBS/PTS
Weight (lb/kg) |
7.0/3.2 |
| MBS/PTS
Mounting |
Shelf
or 19" rack mount |
| MBS/PTS
Input Connection |
Terminal
Block |
| MBS/PTS
Output Connection to Loads |
Terminal
Block |
| MBS/PTS
Output Connection to UPS |
6
foot cable ready for hard wire to UPS terminal
block |
| MBS/PTS
Cooling |
Convection
(approx 7 W contractor coil dissipation) |
| CERTIFICATIONS
AND APPROVALS |
| Electric
Safety |
UL-1778,
CSA-170.1, UL-1950 |
| EMI |
FCC
Class A |
| Surge
Immunity |
Tested
to: IEC 1000-4-5, IEEE C62.41 |
NOTES:
1. Between 55° and 74°C, the unit is de-rated
to a maximum rectified-capacitive load of 1500VA /
1200W
2. De-rate operating temperature above 4900 ft (1500m)
by 2°C per additional 1000 ft (300m) |
|
 |
 |
|
| |
| FUNCTIONS |
| Brownout
Protection |
Unit
boosts output voltage (or transfers to battery) during
brownout or low input line conditions and returns
to normal when input power stabilizes over user-selected
time period.
Setpoints for Transfer / Retransfer, To / From Battery
/ Boost are users programmable. |
| Generator
Compatibility |
Generator
mode allows wider variation in input voltage and frequency
for use with an AC generator |
| Battery
Charger 10 A |
PFC
switch-mode, two-stage charger, temperature compensated
(-2.5 to -5 mV/°C/cell), auto shuttoff about 50°C |
| Inverter
Mode |
Capable
of running continuously in inverter mode |
| Inverter
Mode Current Limit |
Continuous
electronic current limit is provided |
| Remote
Monitoring |
-
Input and out put voltages
- Input line frequency
- Output power
- Battery voltage
- Battery temperature |
| CONTROL
TERMINAL BLOCK |
| Functions |
A.
Provides 6 sets of programmable contacts at pin
1 thu pin 18 for intersection flash control, Remote
Alarms, Pagers or other user interface.
1.
"Low Batt": batteries have reached approximately
40% capacity remaining
2.
"On Batt": unit is in inverter mode
3.
"Timer": unit has been in inverter mode
for 2 hours (programmable)
4.
"Alarm": any of the following conditions
occur:
a.
Line Frequency error
b.
Low Output voltage
c.
No Temperature Probe
d.
Overload
e.
No battery connected
f.
High temperature
g.
Low temperature
5.
"Fault": any of the following conditions
occur:
a.
Short circuit
b.
Batt low voltage
c.
Batt high voltage
d.
High temperature
e.
Overload
B. Provides 48 VDC signal to PTS on pins 21 &
22
C. Triggers self-test by momentarily shorting pin
19 & 20 with less than 100 ohm |
| Contact
Type |
Form
C. Dry contacts rated 1 Amp at 240 V |
| Wiring |
Uses
14-26 AWG |
| COMMUNICATIONS |
| RS-232/USB/Ethernet
ports |
Monitors, controls with terminal emulation software |
| RS-232 |
DB-9,
Female, Opto-Isolated, straight-thru cable |
| USB |
B-Type
receptacle |
| Ethernet
(Optional) |
10/100
Mbps Ethernet, auto-detected |
| Display
Panel |
2-line
LCD |
NOTE:
Specifications subject to change without notice.
|
 |
 |
 |
 |
 |
|