Description
Applications
Medical & Imaging
Industrial Automation
Process & Motion Control
Laboratory, Test &
Measurement
OEM (Original Equipment
Manufacturer)
Communications &
Guidance
Security & Safety
Financial & Banking
Information Technology
Lighting and Commercial
Control
Telephony
 
Features & Benefits
True on-line double conversion topology
True sine-wave output with less than 3% THD
Output voltage regulation to within +/- 2%
High Efficiency (HE) & Free-run mode
EPO (Emergency Power Off) port
Power monitoring & UPS control software
RS-232 & USB communication interface
Multi-function, interactive control panel & LCD display
Input power factor correction, frequency & bypass mode
"Cold Start" power-up & 'Gen-Set compatibility' mode
External battery pack connector (for matching EBP's)
Optional SNMP & AS/400 dry-contact card slot
"Hot-swappable" battery modules
50/60Hz frequency auto-sensing (or free-run)
Overload & short-circuit protection
LED indicators & programmable audible alarms
AC and network (RJ-45) surge protection
Agency Standards
& Compliance
UL 1778, cUL Listed, CE on 220V models
FCC Compliant
ISO 9001 Certified
Warranty
3-year warranty
on parts & labor
2-year on battery
Connected equipment warranty:
$25,000 for all models.
Please see complete warranty
for details.
   
Rear Views





 

     
The Vault series is our latest, state-of-the art range. Featuring true on-line, double-conversion technology with power factor correction, they are ideal for the most critical and sensitive applications where the best level of power protection is required. Connected equipment is not only immune to even the slightest power fluctuations, but is also protected from other power anomalies such as spikes, surges, noise, extended under- and over-voltages, harmonics and frequency variations.

An extremely wide input voltage tolerance (up to +/- 40%) and an output voltage regulation of within +/- 2% make the Vault one of the most flexible and technologically-advanced UPS's on the market. Aside from the traditional Tower form-factor, they would be soon available in rack mount configuration.

Usual features such as UPS & power-monitoring software, integral auto-bypass, 'hot-swappable' batteries, various communication options, extended run-time capability, cold-start, advanced battery management and microprocessor control, are all standard. However, a host of unique features and options bring some exclusivity to the series. They include a High Efficiency & Free-run mode, an EPO (Emergency Power Off) port and load segmentation control.

The units also feature a unique, user-friendly and interactive, multifunction LCD panel that not only displays various UPS and related parameters, but allows the user to check, test and change settings such as output voltage, input and bypass modes from the front panel while the unit is on line. Matching external battery packs (EBP) allow for extended backup-time applications.
   
Product Specifications
 
 
 
Power Monitoring & UPS Control Software
     

Advises on UPS status and monitors power 

disturbances

Indicates battery level, utilized capacity, voltage,  

frequency

Allows manual or automatic controlled shutdown

Allows the auto-test sequence to be initiated

Provides real-time graphic displays of the above

   
Accessories
     

Optional accessories for each series are shown in their respective sections. Please contact us for information on custom or other accessories such as cables, mounting hardware, extended run-time battery packs, software options, etc. Information on the following options can be dowloaded here:


Marathon Power AS-400 Relay Card.pdf
Marathon Power AS-400 Relay Card Schematic.pdf
Marathon Power SNMP/Web Card "Net Agent".pdf

Marathon Power Vault RM2U 5-in-1 Brackets.pdf
Vault 4000T and 5000T UPS Dimensional Drawing.pdf
Vault 4000T and 5000T UPS Dimensional Drawing
with Seismic Mounting Brackets.pdf
Vault 4000RM and 5000RM UPS Dimensional
Drawing.pdf
Vault 6000~10000T EBP Dimensional Drawings.pdf
Vault 6000T EBP Dimensional Drawing.pdf
Vault 6000T UPS Dimensional Drawing.pdf
Vault 6000T Mounting Bracket Dimensional
Drawing.pdf
Vault 6000T Mounting Diagrams.pdf
Vault 6000RM UPS Dimensional Drawings.pdf
Vault 8000~10000T no-ISO Dimensional Drawings.pdf
Vault 8000~10000RM UPS Dimensional Drawings.pdf
Vault 10000T ISO Rear Panel with Bypass Switch.pdf

   
Replacement Batteries
     
For battery replacement under warranty, please contact us directly.
To purchase new batteries, please either contact us or one of the following manufacturer’s directly:
www.csb-battery.com
www.power-sonic.com
www.yuasabatteries.com
 
Software and Communication
     

Various versions of the standard UPS Control & Power Monitoring are available. If your version is not shown here or you are unsure as to which you require, please contact us.

UPSMON Plus V2.89m3 for Windows 95/98/Me/
NT/2000/XP/Server 2003/Vista/Windows 7/
Server 2008, Novell Netware and Linux
Software User Manual for V2.89m3.pdf

UPSMON Plus V2.86 for
Windows 95/98/Me/NT/2000/XP/Server 2003/
Vista/Server 2008, Novell Netware and Linux
Software User Manual for V2.86.pdf

UPSMON Plus V2.85 for
Windows 95/98/Me/NT/2000/XP/Server 2003/
Vista/Server 2008, Novell Netware and Linux
Software User Manual for V2.85.pdf

UPSMON Plus V2.743c for
Windows 95/98/Me/NT/2000/XP
Software User Manual for V2.7x.pdf

SNMP / Web Software "Net Agent" Brochure
SNMP / Web Software "Net Agent" Software
SNMP / Web Card "Net Agent" User Manual

"NetAgent" Network Card User Setup Guide.pdf

Vault Series UPS RS-232 Protocol.pdf

   
Product Warranty
     
Please download our warranty for detailed information on what is covered and what is not as well as how to go about making a warranty claim.
Product Warranty & Return Policy,pdf
10-year Pro-Rated Warranty.pdf
   
Product Registration
     
To register your product and ensure that it will be covered under warranty, please either mail or fax a fully completed registration form to us within 30 days of purchase.
Product Registration.pdf
   
Back-Up Times for Models with EBP

Vault 4000 Backup Time Chart
Vault 5000 Backup Time Chart

Vault 6000 Backup Time Chart
Vault 8000 Backup Time Chart
Vault 10000 Backup Time Chart

Vault 12000 Backup Time Chart

Configuration
Vault 4000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4 kVA
55
30
20
16
12
9
7
6
5
4
4 kVA + 1 Battery Pack
210
125
84
68
50
40
35
30
26
23
4 kVA + 2 Battery Packs
380
230
155
125
95
78
66
57
50
44
4 kVA + 3 Battery Packs
560
340
230
185
144
117
100
85
76
67
4 kVA + 4 Battery Packs
750
460
317
250
195
159
136
116
104
91
 
1. 4 kVA : 10 PCS 12V/7AH Battery
2. 4 kVA Battery Pack: 10*2 12V/7AH Battery


Configuration
Vault 5000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
5 kVA
48
29
19
15
11
9
8
6
5
4
5 kVA + 1 Battery Pack
160
95
63
51
39
31
26
22
19
16
5 kVA + 2 Battery Packs
300
175
120
95
73
60
51
43
38
33
5 kVA + 3 Battery Packs
430
260
175
142
110
90
77
65
58
51
5 kVA + 4 Battery Packs
580
350
240
192
148
120
104
88
79
70
 
1. 5 kVA : 10 PCS 12V/10AH Battery
2. 5 kVA Battery Pack: 10*2 12V/7AH Battery


Configuration
Vault 6000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
6 kVA
78
45
30
24
17
14
11
9
8
7
6 kVA + 1 Battery Pack
300
175
120
96
73
60
51
43
38
33
6 kVA + 2 Battery Packs
530
320
220
176
136
110
95
81
72
63
6 kVA + 3 Battery Packs
780
470
330
260
200
165
142
120
108
95
6 kVA + 4 Battery Packs
1000
630
430
350
270
220
190
164
147
128
 
1. 6 kVA : 20 PCS 12V/7AH Battery
2. 6 kVA Battery Pack: 20*2 12V/7AH Battery


Configuration
Vault 8000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
8 kVA
55
30
20
16
12
9
7
6
5
4
8 kVA + 1 Battery Pack
210
125
84
68
50
40
35
30
26
23
8 kVA + 2 Battery Packs
380
230
155
125
95
78
66
57
50
44
8 kVA + 3 Battery Packs
560
340
230
185
144
117
100
85
76
67
8 kVA + 4 Battery Packs
750
460
317
250
195
159
136
116
104
91
 
1. 8 kVA : 20 PCS 12V/7AH Battery
2. 8 kVA Battery Pack: 20*2 12V/7AH Battery


Configuration
Vault 10000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
10 kVA
48
29
19
15
11
9
8
6
5
4
10 kVA + 1 Battery Pack
160
95
63
51
39
31
26
22
19
16
10 kVA + 2 Battery Packs
300
175
120
95
73
60
51
43
38
33
10 kVA + 3 Battery Packs
430
260
175
142
110
90
77
65
58
51
10 kVA + 4 Battery Packs
580
350
240
192
148
120
104
88
79
70
 
1. 10 kVA : 20 PCS 12V/9AH Battery
2. 10 kVA Battery Pack: 20*2 12V/7AH Battery


Configuration
Vault 12000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
12 kVA
79
45
30
24
17
14
11
9
8
7
12 kVA + 1 Battery Pack
180
108
70
58
44
36
30
25
22
19
12 kVA + 2 Battery Packs
300
175
120
95
73
60
51
43
38
33
12 kVA + 3 Battery Packs
410
250
165
135
104
84
72
61
55
48
12 kVA + 4 Battery Packs
530
320
220
175
135
110
95
81
72
63
 
1. 12 kVA : 20*2 PCS 12V/7AH Battery
2. 12 kVA Battery Pack: 20*2 12V/7AH Battery
   



Home l Applications l UPS Products l Services l How to Order l Discontinued Products
Customer Support l About Us l News & Events l Contact Us l Site Map


Marathon Power
tel: 310-689-2328 • fax: 310-689-2329


 

Vault Product
Info 700-12k.pdf

Vault UPS Specs
4 k-12k.pdf


Vault User
Manual
4 k-12k.pdf


Vault 2U RM
5-in-1 Brackets.pdf


SNMP &
Web Card.pdf


AS-400
Relay Card.pdf


AS-400
Relay Card
Schematic.pdf


UPS Software
User Manuals


Product
Registration.pdf


Product
Warranty.pdf


10 year
Pro-Rated
Warrant.pdf



Download
Adobe
Acrobat




(Opens Adobe's
Web Site)

 
 
© 2003-2011. Marathon Power & Not Maurice, All Rights Reserved.