INFORMATION

VAULT series

Vault Series

700VA to 12000VA

True On-Line UPS

Top of the line customizable UPS with full power conditioning. Ideal for critical applications where the best level of power protection is required.

Description

The Vault series is our latest, state-of-the art range. Featuring true on-line, double-conversion technology with power factor correction, they are ideal for the most critical and sensitive applications where the best level of power protection is required. Connected equipment is not only immune to even the slightest power fluctuations, but is also protected from other power anomalies such as spikes, surges, noise, extended under- and over-voltages, harmonics and frequency variations.

An extremely wide input voltage tolerance (up to +/- 40%) and an output voltage regulation of within +/- 2% make the Vault one of the most flexible and technologically-advanced UPS’s on the market. Aside from the traditional Tower form-factor, they’re also available in 1U or 2U Rack-Tower configurations.

Usual features such as UPS & power-monitoring software, integral auto-bypass, ‘hot-swappable’ batteries, various communication options, extended run-time capability, cold-start, advanced battery management and microprocessor control, are all standard. However, a host of unique features and options bring some exclusivity to the series. They include a High Efficiency & Free-run mode, an EPO (Emergency Power Off) port and load segmentation control.

The units also feature a unique, user-friendly and interactive, multifunction LCD panel that not only displays various UPS and related parameters, but allows the user to check, test and change settings such as output voltage, input and bypass modes from the front panel while the unit is on line. Matching external battery packs (EBP) allow for extended backup-time applications.

Power Monitoring & UPS Control Software

  • Advises on UPS status and monitors power disturbances
  • Indicates battery level, utilized capacity, voltage, and frequency
  • Allows manual or automatic controlled shutdown
  • Allows the auto test sequence to be initiated
  • Provides real-time graphic displays of the above

Features and Benefits

• True on-line double conversion topology
• True sine-wave output with less than 3% THD
• Output voltage regulation to within +/- 2%
• High Efficiency (HE) & Free-run mode
• EPO (Emergency Power Off) port
• Power monitoring & UPS control software
• RS-232 & USB communication interface
• Multi-function, interactive control panel & LCD display
• Input power factor correction, frequency & bypass mode
• “Cold Start” power-up & ‘Gen-Set compatibility’ mode
• External battery pack connector (for matching EBP’s)
• Optional SNMP & AS/400 dry-contact card slot
• “Hot-swappable” battery modules
• 50/60Hz frequency auto-sensing (or free-run)
• Overload & short-circuit protection
• LED indicators & programmable audible alarms
• AC and network (RJ-45) surge protection

UPS Specifications

120 V Model Specifications – 700 – 3000VA
230 V Model Specifications – 700 – 3000VA
700VA to 3000VA – Models Specifications
4000VA to 12000VA – Models Specifications

120 V Model Specifications – 700 – 3000VA

GENERAL
Rated Capacity: 700VA, 1000VA, 1500VA, 2000VA, 3000VA with a power factor of 0.7
Technology: True on-line, double conversion topology with integral automatic bypass
INPUT
Phase: Single phase plus ground
Bypass Voltage 96 – 138 VAC (user selectable)
Input Voltage Range: 60 / 70 / 80VAC – 144 VAC (60V @ 40%, 70V @ 70%, 80V @ 100% load)
Frequency: 50 / 60 Hz Auto sensing
AC Frequency range: 45 – 65 Hz
Synchronization range: ± 3Hz
Input Current (120V): 700VA – 5.8A, 1000VA – 8.2A, 1500VA – 12.4A, 2000VA – 16.5A, 3000 VA – 24.7A
Input Power factor: 0.97
OUPUT
Output Voltage: 100 / 110 / 115 / 120 / 127 VAC (user selectable)
Voltage regulation: ± 2%
Voltage distortion: < 5% THD with non-linear loads, < 3% THD with linear loads
Frequency regulation: ± 0.25 Hz (while on battery or in free run mode)
Dynamic response: ± 9 % max from 100% to 20 % or from 20% to 100 % linear load
Overload capacity: 100 – 125% for 1 min, 125 – 150 % for 10 sec
Efficiency (HE Mode): Greater than 95%
Efficiency (On-line Mode): Greater than 86%
Crest Factor: 3 : 1

120V TOWER MODELS

Model Number
VTWE-0700-01
VTWE-1000-01
VTWE-1500-01
VTWE-2000-01
VTWE-3000-01
Capacity
700VA
490 W
1000VA
700W
1500VA
1050W
2000VA
1400WA
3000VA
2100W
Input Connection
Fixed power cord
Output Connection
6 x NEMA 5-15R
12 x NEMA 5-15 R
Battery Type & Rating
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9Ah/12V
Battery Quantity
2
3
3
6
6
Backup Time (full load)
7 min
6 min
5 min
6 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
6 x 16.5 x 9.4
152 x 420 x 238
8.9 x 16.7 x 14.2
225 x 425 x 360
Weight lbs/kg (net)
29.7 / 13.5
35.7 / 16.2
37.4 / 17
69.5 / 31.6
72.6 / 33

120V 19″ Rack-mount Models (2U)

Model Number
VRTE-0700-01
VRTE-1000-01
VRTE-1500-01
VRTE-2000-01
VRTE-3000-01
Capacity
700VA
490 W
1000VA
700W
1500VA
1050W
2000VA
1400WA
3000VA
2100W
Input Connection
Fixed power cord
Output Connection
6 x NEMA 5-15R
4 x NEMA 5-15 R
Battery Type & Rating
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9 Ah/12V
Battery Quantity
2
3
3
6
6
Backup Time (full load)
7 min
6 min
5 min
6 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
16.9 x 16.7 x 3.3
428 x 425 x 84
16.9 x 24 x 3.3
428 x 610 x 84
Weight lbs/kg (net)
32 / 14.6
38 / 17.3
39.8 / 18.1
69.5 / 31.6
72.6 / 33

120V 19″ Rack-mount Models (1U)

Model Number
VRME-0700-01
VRME-1000-01
Capacity
700VA
490 W
1000VA
700W
Input Connection
Fixed power cord
Output Connection
4 x IEC 320 (10A)
3 x NEMA 5-15R
Battery Type & Rating
Sealed, lead-acid
7Ah/6V
Battery Quantity
4
Backup Time (full load)
6 min
4 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
16.9 x 20.7 x 1.73
428 x 525 x 44
Weight lbs/kg (net)
34.1 / 15.5

A hardwire version of all models is available. For model number, substitute the last two digits of the model number for H1 (120V) or H2 (220V).

230 V Model Specifications – 700 – 3000VA

GENERAL
Rated Capacity: 700VA, 1000VA, 1500VA, 2000VA, 3000VA with a power factor of 0.7
Technology: True on-line, double conversion topology with integral automatic bypass
INPUT
Phase: Single phase plus ground
Bypass Voltage 184 – 265 VAC (user selectable)
Input Voltage Range: 120 / 140 / 160 VAC – 276 VAC (120V @ 40%, 140V @ 70%, 160V @ 100% load)
Frequency: 50 / 60 Hz Auto sensing
AC Frequency range: 45 – 65 Hz
Synchronization range: ± 3Hz
Input Current (120V): 700VA – 3A, 1000VA – 4A, 1500VA – 5.7A, 2000VA – 7.7A, 3000VA – 12A
Input Power factor: 0.97
OUPUT
Output Voltage: 208 / 220 / 230 / 240 VAC (user selectable)
Voltage regulation: ± 2%
Voltage distortion: < 5% THD with non-linear loads, < 3% THD with linear loads
Frequency regulation: ± 0.25 Hz (while on battery or in-free run mode)
Dynamic response: ± 9 % max from 100% to 20 % or from 20% to 100 % linear load
Overload capacity: 100 – 125% for 1 min, 125 – 150 % for 10 sec
Efficiency (HE Mode): Greater than 95%
Efficiency (On-line Mode): Greater than 86%
Crest Factor: 3 : 1

230V TOWER MODELS

Model Number
VTWE-0700-02
VTWE-1000-02
VTWE-1500-02
VTWE-2000-02
VTWE-3000-02
Capacity
700VA
490 W
1000VA
700W
1500VA
1050W
2000VA
1400WA
3000VA
2100W
Input Connection
IEC 320 (10A)
IEC 320 (16A)
Output Connection Options
4 x IEC 320 (10A)
8 x IEC 320 (10A),
1x IEC 320 (16A)
4x NEMA 6-15R
12 x NEMA 6-15 R
2 x European
6 x European, 1x IEC 320 (16A)
Battery Type & Rating
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9 Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9 Ah/12V
Battery Quantity
2
3
3
6
6
Backup Time (full load)
5 min
6 min
5 min
6 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
6 x 16.5 x 9.4
152 x 420 x 238
8.9 x 16.7 x 14.2
22 5 x 428 x 360
Weight lbs/kg (net)
29.7 / 13.5
35.7 / 16.2
37.4 / 17
69.5 / 31.6
72.6 / 33

230V 19″ Rack-mount Models (2U)

Model Number
VRTE-0700-02
VRTE-1000-02
VRTE-1500-02
VRTE-2000-02
VRTE-3000-02
Capacity
700VA
490 W
1000VA
700W
1500VA
1050W
2000VA
1400WA
3000VA
2100W
Input Connection
IEC 320 (10A)
IEC 320 (16A)
Output Connection Options
4 x IEC 320 (10A)
8 x IEC 320 (10A),
1x IEC 320 (16A)
4x NEMA 6-15R
12 x NEMA 6-15 R
2 x European
6 x European, 1 x IEC 320 (16A)
Battery Type & Rating
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
9 Ah/12V
Battery Quantity
2
3
3
6
6
Backup Time (full load)
5 min
6 min
5 min
6 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
16.9 x 16.7 x 3.3
428 x 425 x 84
16.9 x 24 x 3.3
428 x 610 x 84
Weight lbs/kg (net)
32 / 14.6
38 / 17.3
39.8 / 18.1
69.5 / 31.6
72.6 / 33

230V 19″ Rack-mount Models (1U)

Model Number
VRME-0700-02
VRME-1000-02
Capacity
700VA
490 W
1000VA
700W
Input Connection
IEC 320(10A)
Output Connection
4 x IEC 320 (10A)
3 x 6-15R (USA)
Battery Type & Rating
Sealed, lead-acid
7Ah/6V
Battery Quantity
4
4
Backup Time (full load)
6 min
4 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
16.9 x 20.7 x 1.73
428 x 525 x 44
Weight lbs/kg (net)
34.1 / 15.5

A hardwire version of all models is available. For model number, substitute the last two digits of the model number for H1 (120V) or H2 (220V).

700VA to 3000VA – Models Specifications

STANDARDS
Safety: EN50091-1-1
Emissions: EN50091-2 class B
Immunity: EN50091-2
Conformity: UL 1778, cUL 107.1, 107.2, CE
Transient Immunity (120V): Per IEEE 62.41 (formerly IEEE 587)
Transient Immunity (230V): Per IEEE C 61000-4-5 level 3
ENVIRONMENTAL
Ambient temperature range: +32 °F to +104°F (+0 °C to +40 °C)
Optimum temperature range: +59 °F to +77°F (+15 °C to +25 °C)
Storage temperature: +5 °F to +122°F (-15 °C to +50 °C)
Cooling: Forced air cooling
Humidity:: 0-95%, non-condensing
Elevation: 10,000 feet max (operation), 45,000 feet (storage)
Audible noise: < 45 db normal and battery mode (700-1000 VA models)
< 52 db normal and battery mode (1500-3000 VA models)
MODEL & PART NUMBER DESIGNATION
120V Tower Models: VTWE-0700-01, VTWE-1000-01, VTWE-1500-01, VTWE-2000-01, VTWE-3000-01
230V Tower Models: VTWE-0700-02, VTWE-1000-02, VTWE-1500-02, VTWE-2000-02, VTWE-3000-02
120V Rack-Tower Models (1U): VRME-0700-01, VRME-1000-01
230V Rack-Tower Models (1U): VRME-0700-02, VRME-1000-02
120V Rack-Tower Models (2U): VRTE-0700-01, VRTE-1000-01, VRTE-1500-01, VRTE-2000-01, VRTE-3000-01
230V Rack-Tower Models (2U): VRTE-0700-02, VRTE-1000-02, VRTE-1500-02, VRTE-2000-02, VRTE-3000-02

4000VA to 12000VA – Models Specifications

GENERAL
Rated Capacity: 4kVA, 5kVA, 6kVA, 8kVA, 10kVA, 12kVA with a power factor of 0.7
Technology: True on-line, double conversion topology with integral automatic bypass
INPUT
Phase: Single phase plus ground
Input Bypass Voltage 184 – 265 VAC (+15% to -20% of 230 V nominal,
user selectable)
Input Voltage Tolerance: 120V – 276V @ 25% load,
140V – 276V @ 50% load,
160V – 276V @ 75% load,
180V – 276V @ 100% load
Frequency: 50 / 60 Hz Auto sensing
AC Frequency range: 45 – 65 Hz
Synchronization range: ± 3Hz
Input Current: 4kVA – 15A, 5kVA – 19, 6kVA – 23A, 8kVA – 30A,
10kVA – 38A, 12kVA – 46A
Input Power factor: 0.97
OUPUT
Output Voltage: 208 / 220 / 230 / 240 VAC (user selectable)
Voltage regulation: ± 2%
Voltage distortion: <5% THD with non-linear loads, <3% THD with linear loads
Frequency regulation: ± 0.25 Hz (while on battery or in free run mode)
Dynamic response: ± 9% max from 100% to 20% or from 20% to 100%
linear load
Overload capacity: 100 – 125% for 1 min, 126 – 150 % for 10 sec
Efficiency (HE Mode): Greater than 95%
Efficiency (On-line Mode): Greater than 88%
Crest Factor: 3 : 1
ENVIRONMENTAL
Ambient temperature range: +32 °F to +104°F (+0 °C to +40 °C)
Optimum temperature range: +59 °F to +77°F (+15 °C to +25 °C)
Storage temperature: +5 °F to +122°F (-15 °C to +50 °C)
Cooling: Forced air cooling
Humidity:: 0-95%, non-condensing
Elevation: 10,000 feet max (operation), 45,000 feet (storage)
Audible noise: < 55 db normal and battery mode (4000-8000 VA models)
< 55 db normal and battery mode (10000-12000 VA models)
STANDARDS
Safety: EN50091-1-1
Emissions: EN50091-2 class B
Immunity: EN50091-2
Conformity: UL 1778, CSA 107.1, 107.2, CE
Transient Immunity: Per IEEE C 61000-4-5 level 3

TOWER MODELS

Model Number
VTWE-
4000-02
VTWE-
5000-02
VTWE-
6000-02
VTWE-
8000-02
VTWE-
10000-02
VTWE-
12000-02
Capacity
4kVA
2.8kW
5kVA
3.5kW
6kVA
4.2kW
8kVA
5.6kW
10kVA
7kW
12kVA
8.4kW
Input Connection
Hardwire Terminal
Block or Fixed
Hardwire Terminal Block
Output Connection Options
IEC 320 10A and 16A
Hardwire Terminal Block and/or
various IEC Receptacles
IEC and NEMA L6-30R
Hardwire Terminal Block and/or
various NEMA Receptacles
IEC and Shuko (European)
Hardwire Terminal Block and/or
various European Receptacles
Battery Type & Rating
Sealed,
lead-acid
7.2Ah/12V
Sealed,
lead-acid
9Ah/12V
Sealed,
lead-acid
7.2Ah/12V
Sealed,
lead-acid
7.2Ah/12V
Sealed,
lead-acid
9 Ah/12V
Sealed,
lead-acid
7.2Ah/12V
Battery Quantity
10
10
20
20
20
40
Backup Time
(full load)
6 min
6 min
7 min
5 min
6 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H

10.1 x 21.1 x 17.3257 x 537 x 440

10.2 x 27.6
x 27.6
258 x 700
x 700

10.1 x 27.2 x 28257 x 690 x 715

13.5 x 27
x 34.6
342 x 690
x 878
Weight lbs/kg
95 / 43
176 / 80
189 / 86
286 / 130

19″ RACK-MOUNT MODELS

Model Number
VRTE-
4000-02
VRTE-
5000-02
VRTE-
6000-02
VRTE-
8000-02
VRTE-
10000-02
VRTE-
12000-02
Capacity
4kVA
2.8kW
5kVA
3.5kW
6kVA
4.2kW
8kVA
5.6kW
10kVA
7kW
12kVA
8.4kW
Input Connection
Hardwire Terminal Block or Fixed
Output Connection Options
Hardwire Terminal Block and various IEC Receptacles
Hardwire Terminal Block and various NEMA Receptacles
Hardwire Terminal Block and various European Receptacles
Battery Type & Rating
Sealed,
lead-acid
5Ah/12V
Sealed,
lead-acid
5Ah/12V
Sealed,
lead-acid
7.2Ah/12V
Sealed,
lead-acid
7.2Ah/12V
Sealed,
lead-acid
9 Ah/12V
Sealed,
lead-acid
9Ah/12V
Battery Quantity
10
10
20
20
20
40
Backup Time* (full load)
4 min
3 min
7 min
5 min
6 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
16.9 x 25.9 x 10.3
428 x 657 x 260
16.9 x 23.6
x 10.3
428 x 597
x 260
16.9 x 25.9 x 10.3
428 x 657 x 260
Weight lbs/kg
88 / 40
189 / 86
203 / 92

EBP Specifications

TOWER MODEL EXTENDED BATTERY PACKS

Model Number
VBPT-0014-36
VBPT-0014-72
Capacity
700VA
1000VA
1500VA
2000VA
3000VA
Input Connection
Fixed cord with color-coded Anderson connector
Output Connection
Panel mounted, color-coded Anderson connector
Battery Type
& Rating
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2 Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Battery Quantity
6
6
6
12
12
Backup Time
(full load)
See run-time table below
Recharge Time
<8 hours to 90 %
Dimensions ins/mm
W x D x H
6 x 16.5 x 9.4
152 x 420 x 238
8.9 x 16.7 x 14.2
225 x 425 x 360
Weight lbs/kg (net)
46.2 / 21
92.4 / 42

 


19″ RACK-MOUNT EXTENDED BATTERY PACKS (2U)

Model Number
VBPR-0014-36
VBPR-0014-72
Capacity
700VA
1000VA
1500VA
2000VA
3000VA
Input Connection
Fixed cord with color-coded Anderson connector
Output Connection
Panel mounted, color-coded Anderson connector
Battery Type
& Rating
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2 Ah/12V
Sealed, lead-acid
7.2Ah/12V
Sealed, lead-acid
7.2Ah/12V
Battery Quantity
6
6
6
12
12
Backup Time
(full load)
See run-time table below
Recharge Time
<8 hours to 90 %
Dimensions ins/mm
W x D x H
16.9 x 16.7 x 3.3
428 x 425 x 84
16.9 x 24 x 3.3
428 x 610 x 84
Weight lbs/kg (net)
48.4 / 22
95.7 / 43.5

 

Run-Times at Various Loads (Tower & 19″ Rack-Mount Models)

Load Level
Model
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Vault 700VA
85
44
27
20
15
12
9
8
7
6
Vault 700 (7.2Ah x 2)
+ 1 EBP (7.2Ah x 6)
380
280
170
140
100
78
72
60
50
43
Vault 700 (7.2Ah x 2)
+ 2 EBP (7.2Ah x 12)
750
450
340
280
210
170
150
120
105
90
Vault 1000VA
85
45
29
20
16
12
9
8
7
6
Vault 1000 (7.2Ah x 3)
+ 1 EBP (7.2Ah x 6)
330
200
130
95
80
60
50
40
38
33
Vault 1000 (7.2Ah x 3)
+ 2 EBP (7.2Ah x 12)
500
380
245
190
150
115
96
78
76
66
Vault 1500VA
50
30
20
16
13
10
8
7
6
5
Vault 1500 (9Ah x 3)
+ 1 EBP (7.2Ah x 6)
210
120
80
60
42
35
28
24
20
18
Vault 1500 (9Ah x 3)
+ 2 EBP (7.2Ah x 12)
400
210
130
115
80
72
60
48
40
38
Vault 2000VA
85
45
29
20
16
12
9
8
7
6
Vault 2000 (7.2Ah x 6)
+ 1 EBP (7.2Ah x 12)
330
200
130
95
80
60
50
40
38
33
Vault 2000 (7.2Ah x 6)
+ 2 EBP (7.2Ah x 24)
500
380
245
190
150
115
96
78
76
66
Vault 3000VA
50
30
20
16
13
10
8
7
6
5
Vault 3000 (9Ah x 6)
+ 1 EBP (7.2Ah x 12)
210
120
80
60
42
35
28
24
20
18
Vault 3000 (9Ah x 6)
+ 2 EBP (7.2Ah x 24)
400
210
130
115
80
72
60
48
40
38

Note: One (1) battery pack contains two battery strings.

 

Back-Up Times for Standard Models

Back-Up Times are given in minutes.

 

Configuration
Vault 4000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
4kVA
55
30
20
16
12
9
7
6
5
4
4kVA + 1 Battery Pack
210
125
84
68
50
40
35
30
26
23
4kVA + 2 Battery Packs
380
230
155
125
95
78
66
57
50
44
4kVA + 3 Battery Packs
560
340
230
185
144
117
100
85
76
67
4kVA + 4 Battery Packs
750
460
317
250
195
159
136
116
104
91
1. 4kVA : 10 PCS 12V/7AH Battery
2. 4kVA Battery Pack: 10*2 12V/7AH Battery

 

Configuration
Vault 5000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
5kVA
48
29
19
15
11
9
8
6
5
4
5kVA + 1 Battery Pack
160
95
63
51
39
31
26
22
19
16
5kVA + 2 Battery Packs
300
175
120
95
73
60
51
43
38
33
5kVA + 3 Battery Packs
430
260
175
142
110
90
77
65
58
51
5kVA + 4 Battery Packs
580
350
240
192
148
120
104
88
79
70
1. 5kVA : 10 PCS 12V/10AH Battery
2. 5kVA Battery Pack: 10*2 12V/7AH Battery

 

Configuration
Vault 6000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
6kVA
78
45
30
24
17
14
11
9
8
7
6kVA + 1 Battery Pack
300
175
120
96
73
60
51
43
38
33
6kVA + 2 Battery Packs
530
320
220
176
136
110
95
81
72
63
6kVA + 3 Battery Packs
780
470
330
260
200
165
142
120
108
95
6kVA + 4 Battery Packs
1000
630
430
350
270
220
190
164
147
128
1. 6kVA : 20 PCS 12V/7AH Battery
2. 6kVA Battery Pack: 20*2 12V/7AH Battery

 

Configuration
Vault 8000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
8kVA
55
30
20
16
12
9
7
6
5
4
8kVA + 1 Battery Pack
210
125
84
68
50
40
35
30
26
23
8kVA + 2 Battery Packs
380
230
155
125
95
78
66
57
50
44
8kVA + 3 Battery Packs
560
340
230
185
144
117
100
85
76
67
8kVA + 4 Battery Packs
750
460
317
250
195
159
136
116
104
91
1. 8kVA : 20 PCS 12V/7AH Battery
2. 8kVA Battery Pack: 20*2 12V/7AH Battery

 

Configuration
Vault 10000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
10kVA
48
29
19
15
11
9
8
6
5
4
10kVA + 1 Battery Pack
160
95
63
51
39
31
26
22
19
16
10kVA + 2 Battery Packs
300
175
120
95
73
60
51
43
38
33
10kVA + 3 Battery Packs
430
260
175
142
110
90
77
65
58
51
10kVA + 4 Battery Packs
580
350
240
192
148
120
104
88
79
70
1. 10kVA : 20 PCS 12V/9AH Battery
2. 10kVA Battery Pack: 20*2 12V/7AH Battery

 

Configuration
Vault 12000 Backup Time Chart (in Minutes)
Load
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
12kVA
79
45
30
24
17
14
11
9
8
7
12kVA + 1 Battery Pack
180
108
70
58
44
36
30
25
22
19
12kVA + 2 Battery Packs
300
175
120
95
73
60
51
43
38
33
12kVA + 3 Battery Packs
410
250
165
135
104
84
72
61
55
48
12kVA + 4 Battery Packs
530
320
220
175
135
110
95
81
72
63
1. 12kVA : 20*2 PCS 12V/7AH Battery
2. 12kVA Battery Pack: 20*2 12V/7AH Battery

 

Applications

• Medical & Imaging*
• Industrial Automation
• Process & Motion Control
• Laboratory, Test & Measurement
• OEM (Original Equipment Manufacturer)
• Communications & Guidance
• Security & Safety
• Financial & Banking
• Information Technology
• Lighting and Commercial Control
• Telephony

* While our Vault Series units are suited to many applications within the medical and healthcare environment, they are not certified for use with life support systems and other critical care devices.

Accessories & Options

Please contact us for information on custom or other accessories such as cables, mounting hardware, extended run-time battery packs, software options, etc. Information on the following options can be downloaded here:

Communication Options
UPSMON
Dry Contacts
Ethernet
Communications Protocol

Mounting & Installation
5-in-1 Brackets
Universal Mounting Rails

Battery Packs

Software & Drivers

Various versions of the standard UPS Control & Power Monitoring are available.
If your version is not shown here or you are unsure as to which you require, please contact us.

UPSMON
UPSMON V2.90 for Windows
Software User Manual for V2.90

UPSMON Plus V2.86 for Windows
Software User Manual for V2.86

NetPower SNMP / Webcard
Brochure
User Manual
Quick Configuration Guide
User Setup Guide
SNMP / Web Software

NetAgent 9 SNMP / Webcard
Brochure
User Manual
ClientMate for Windows v5.62
Netility for Windows v4.53
SNMPView v.5.73

Photos

Back1500RT

Back3000RT2U

Back1500T

Back3000T

PDF Library

Product Information
Vault Series Product Information

Specifications
700VA – 3kVA
Vault 700-3k Guide Spec
Vault 700-3k UPS Specifications
Vault 700-3k EBP Specifications
Vault 700-3k EBP Drawings
Vault 700T~1500T Drawings
Vault 700T~3000T Hardwire Terminals
Vault 2000T~3000T Drawings
Vault 700RM~1000RM 1U Drawings
Vault 700RT~1500RT 2U Drawings
Vault 2000RT~3000RT Drawings
Vault 2000RT~3000RT Hardwire Terminals
Vault 2000RT~3000RT Nema L5-30R
Vault 2000T~3000T Rear Panel with Nema L5-30R
Vault 4000RT~5000RT with Internal Batteries
Vault 4000RT~5000RT without Internal Batteries

4 kVA- 12kVA
Vault 4k-12k UPS Specifications
Vault 4000T and 5000T UPS Dimensional Drawing
Vault 4000T and 5000T UPS Dimensional Drawing w/ Seismic Mounting Brackets
Vault 4000RM and 5000RM UPS Dimensional Drawing
Vault 6000~10000T EBP Dimensional Drawings
Vault 6000T EBP Dimensional Drawing
Vault 6000T UPS Dimensional Drawing
Vault 6000T Mounting Bracket Dimensional Drawing
Vault 6000T Mounting Diagrams
Vault 6000RM UPS Dimensional Drawings
Vault 8000~10000T no-ISO Dimensional Drawings
Vault 8000~10000RM UPS Dimensional Drawings
Vault 8000T~10000T EBP Dimensional Drawings

Vault 10000T ISO Rear Panel with Bypass Switch

Vault Series UPS RS-232 Protocol

User Manuals
Vault 700-3k UPS User Manual
Vault 700-3k EBP User Manual Rack Mount (VBPR-0014-36 or 72)
Vault 700-3k EBP User Manual Tower (VBPT-0014-36 or 72)
Vault Series Short EBP User Manual (VBRD-0014-72)
Vault Series User Manual 4k-12k
Vault Series User Manual 4k-20k CE Version

Accessories
Vault Series AS 400 Relay Card Brochure
Vault Series 2U RM 5-in-1 Brackets

 

Battery Replacement

For battery replacement under warranty, please contact us directly.

We offer a variety of new replacement batteries for all of our UPS models once the original batteries have exceeded their life expectancy. To purchase new batteries, please either contact us or one of the following manufacturer’s directly:
www.csb-battery.com
www.power-sonic.com
www.yuasabatteries.com

Technical Service Bulletins
Battery Life Expectancy
Battery Maintenance

Certifications

Agency Standards & Compliance
• UL 1778
• cUL Listed
• CE on 220V models
• FCC Compliant
• ISO 9001 Certified

Product Certifications

Warranty

Registration
To register your product and ensure that it will be covered under warranty, please either mail or fax a fully completed registration form to us within 30 days of purchase.
Product Registration

Warranty
3-year warranty on parts & labor 2-year on battery
Connected equipment warranty: $25,000 for all models.

Please download our warranty for detailed information on what is covered and what is not as well as how to go about making a warranty claim.

Product Warranty & Return Policy


Live DemoDownload Center

Marathon Power · tel: 310-689-2328 · fax: 310-689-2329