310.689.2328

**Battery Module

*Electronics Module

*Electronics Module

**Battery Module

Track Series Standard Run-Time Model Specifications

Back-Up Times are given in minutes.

BACK-UP TIMES FOR STANDARD MODELS

Configuration
Tower
19″ Rack-Mount
VA/WATTS
600
VA
1000 VA
1500
VA
2000
VA
3000
VA
600
VA
1000
VA
1500
VA
2000
VA
250 / 150
22
42
70
110
152
20
45
70
105
500 / 300
9
14
26
55
86
8
17
26
52
750 / 450
-
9
19
38
62
-
10
19
35
1000 / 600
-
5
13
25
44
-
5
13
24
1250 / 720
-
-
8
18
33
-
-
8
16
1500 / 900
-
-
5
13
25
-
-
5
11
1800 / 1080
-
-
-
9
21
-
-
-
8
2000 / 1200
-
-
-
5
16
-
-
-
5
2500 / 1500
-
-
-
-
9
-
-
-
-
3000 / 1800
-
-
-
-
5
-
-
-
-

230V STANDARD RUN-TIME 19" RACK-MOUNT MODELS (3U)

Model Number
TRMS-0600-02
TRMS-1000-02
TRMS-1500-02
TRMS-2000-02
Capacity
600VA
360W
1000VA
600W
1500VA
900W
2000VA
1200WA
Input Connection
IEC-C14 Receptacle
Output Connection
4 x IEC-C13 Receptacle
Battery Type & Rating
Battery Quantity
2
2
3
4
Backup Time (full load)
9 min
5 min
5 min
5 min
Recharge Time
<8 hours to 90 %
Dimensions ins/mm
W x D x H
19 x 15 x 5.2
485 x 381 x 130
Weight lbs/kg (net)
38 / 17.3
44 / 20
55 / 25
61.6 / 28

230V STANDARD RUN-TIME 19" RACK-MOUNT MODELS (2U)

Model Number
TRTE-1000-02
TRTE-1440-02
TRTE-2000-02
TRTE-3000-02
Capacity
1000VA
700W
1440VA
1000W
2000VA
1400W
3000VA
2100WA
Input Connection
IEC-C14 Receptacle
IEC-C20 Receptacle
Output Connection
8 x IEC-C13 Receptacle
8 x IEC-C13
Receptacle + 1 x
IEC-C19 Receptacle
Battery Type & Rating
Battery Quantity
2
2
4
4
Backup Time (full load)
9 min
5 min
5 min
5 min
Recharge Time
<8 hours to 90 %
Dimensions ins/mm
W x D x H
19 x 16.9 x 3.3
485 x 430 x 84
19 x 24.2 x 3.3
485 x 615 x 84
Weight lbs/kg (net)
38 / 17.3
44 / 20
55 / 25
95 / 43.2

230V STANDARD RUN-TIME TOWER MODELS

Model Number
TTWS-0600-02
TTWS-1000-02
TTWS-1500-02
TTWS-2000-02

TTWS-3000-02

Capacity
600VA
360W
1000VA
600W
1500VA
900W
2000VA
1200WA
3000VA
1800W
Input Connection
Fixed NEMA 6-15P power cord
Hardwire Terminal
Output Connection
6 x IEC-C13 Receptacle
HW +4 x IEC-C13
Receptacle
Battery Type & Rating
Battery Quantity
2
2
3
4
8
Backup Time (full load)
9 min
5 min
5 min
5 min
5 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
5.6 x 17.2 x 8.3
140 x 436 x 210
6.7 x 17.8 x 8.9
170 x 450 x 226
Weight lbs/kg (net)
31 / 14
33 / 15
56 / 25
66 / 30
20 / 44* | 57 / 26**
Model Number
TRMS-0600-01
TRMS-1000-01
TRMS-1500-01
TRMS-2000-01
Capacity
600VA
360W
1000VA
600W
1500VA
900W
2000VA
1200WA
Input Connection
Removable IEC power cord or fixed power cord
Output Connection
4 x NEMA 5-15 R
Battery Type & Rating
Battery Quantity
2
2
3
4
Backup Time (full load)
9 min
5 min
5 min
5 min
Recharge Time
<8 hours to 90 %
Dimensions ins/mm
W x D x H
19 x 15 x 5.2
485 x 381 x 130
Weight lbs/kg (net)
38 / 17.3
44 / 20
55 / 25
61.6 / 28
Model Number
TTWS-0600-01
TTWS-1000-01
TTWS-1500-01
TTWS-2000-01

TTWS-3000-01

Capacity
600VA
360W
1000VA
600W
1500VA
900W
2000VA
1200WA
3000VA
1800W
Input Connection
Fixed NEMA 5-15P power cord
Hardwire Terminal
Output Connection
6 x NEMA 5-15R
HW + 4 x NEMA 5-15R
Battery Type & Rating
Battery Quantity
2
2
3
4
8
Backup Time (full load)
7 min
5 min
5 min
5 min
6 min
Recharge Time
<4 hours to 90 %
Dimensions ins/mm
W x D x H
5.6 x 17.2 x 8.3
140 x 436 x 210
6.7 x 17.8 x 8.9
170 x 450 x 226
Weight lbs/kg (net)
31 / 14
33 / 15
56 / 25
66 / 30
20 / 44* | 57 / 26**

120V STANDARD RUN-TIME 19" RACK-MOUNT MODELS (3U)

GENERAL

Rated Capacity

600VA, 1000VA, 1500VA, 2000VA, 3000VA with a power factor of 0.6


Technology

Line-interactive topology with true sine wave output on battery


120V STANDARD RUN-TIME MODELS

OUTPUT


Phase

Single phase plus ground


Input Voltages

110V, 115V, 120V or 220V, 230V, 240V


Input Voltage Range

± 25%


Frequency

50 / 60 Hz Auto sensing


AC Frequency range

45 – 65 Hz


Input Current (120V)

600VA – 5A, 1000VA -8.2A, 1500VA -12.4A, 2000VA -16.5A, 3000VA -25A


Input Current (230V)

4kVA – 15A, 5kVA – 19, 6kVA – 23A, 8kVA – 30A, 10kVA – 38A, 12kVA – 46A


Input Protection

Fuse or circuit breaker for overload and short circuit (model dependent)


DC Bus Voltage

600VA – 24V, 1000VA – 24V, 1500VA – 36V, 2000VA – 48V, 3000VA – 96V

Output Voltage

110V, 115V, 120V or 220V, 230V, 240V


Voltage regulation

± 5% (600VA – 3000VA)


Voltage distortion

less than 5% THD with non-linear loads, less than 3% THD with linear loads


Frequency regulation

± 0.5% (while on battery)


Automatic Voltage Regulation

Increases or decreases output voltage by 15% if the input voltage decreases or increases by between 9% and 25%


Transfer Time

Between 4 and 8 milliseconds including detection time


Efficiency (Standby Mode)

Greater than 95%


Overload Capacity

110% for 20 seconds, 125% for 5 seconds

INPUT

TRACK SERIES