COMMUNICATIONS

RS-232/USB/Ethernet ports Monitors, controls with terminal emulation software
RS-232 DB-9, Female, Opto-Isolated, straight-thru cable
USB B-Type receptacle
Ethernet (Optional) 10/100 Mbps Ethernet, auto-detected
Display Panel 2-line LCD

CONTROL TERMINAL BLOCK

Functions A. Provides 6 sets of programmable contacts at pin 1 thu pin 18 for intersection flash control, Remote Alarms, Pagers or other user interface.
1. “Low Batt”: batteries have reached approximately 40% capacity remaining
2. “On Batt”: unit is in inverter mode
3. “Timer”: unit has been in inverter mode for 2 hours (programmable)
4. “Alarm”: any of the following conditions occur:
a. Line Frequency error
b. Low Output voltage
c. No Temperature Probe
d. Overload
e. No battery connected
f. High temperature
g. Low temperature
5. “Fault”: any of the following conditions occur:
a. Short circuit
b. Batt low voltage
c. Batt high voltage
d. High temperature
e. Overload
B. Provides 48 VDC signal to PTS on pins 21 & 22
C. Triggers self-test by momentarily shorting pin 19 & 20 with less than 100 ohm
Contact Type Form C. Dry contacts rated 1 Amp at 240 V
Wiring Uses 14-26 AWG

FUNCTIONS

Brownout Protection Unit boosts output voltage (or transfers to battery) during brownout or low input line conditions and returns to normal when input power stabilizes over user-selected time period.
Setpoints for Transfer / Retransfer, To / From Battery / Boost are users programmable.
Generator Compatibility Generator mode allows wider variation in input voltage and frequency for use with an AC generator
Battery Charger 10 A PFC switch-mode, two-stage charger, temperature compensated (-2.5 to -5 mV/°C/cell), auto shuttoff about 50°C
Inverter Mode Capable of running continuously in inverter mode
Inverter Mode Current Limit Continuous electronic current limit is provided
Remote Monitoring - Input and out put voltages
- Input line frequency
- Output power
- Battery voltage
- Battery temperature

NOTES:
1. Between 55° and 74°C, the unit is

de-rated to a  maximum rectified-capacitive load of 1600VA / 1200W.


2. De-rate operating temperature above 4900 ft (1500m) by 2°C per additional 1000 ft (300m).

Operating Temp °C

-37 to +74°C (See Notes 1 & 2)


Storage Temp °C

-50 to +75°C


Humidity

less than 95% non-condensing


Altitude, ft (m)

10,000 (3000) (See Note 2)


DESIGNED TO CONFORM TO

ENVIRONMENTAL

Meets

TEES, July 2009

2009 TEES Errata 1, Jan. 2010

2009 TEES Errata 2, Dec. 2014

TEES, Ch. 4 - BBS, July 2009


EMI

FCC Class A


Surge Immunity

Tested to: IEC 1000-4-5, IEEE C62.41

PERFORMANCE

Transfer Time

- Controller

- PTS

- TOTAL

4 to 10 ms

less than 30 ms

less than 65 ms


Efficiency, Line Mode

greater than 95% (Resistive Load)


Efficiency, Inverter Mode

greater than 80% (Resistive Load)

Line Interactive UPS Specifications

MECHANICAL

Dimensions
(WxDxH) inch/mm

W 17.5/444 – 19/483 w/flange
D 10.5/267
H 5.25/133 – 3 U




Weight (lb/kg)

46.2/21


Mounting

19″ (483 mm) rak or shelf mount


Input Connection

Anderson PowerPole Connector


Output Connection to Loads

Anderson PowerPole Connector


Cooling

Microprocessor controlled, 12 VDC, 3.2″ (80 mm) fan


Audible Noise Level, dBA

<40


MBS/PTS Dimensions

(WxDxH) inch/mm

W 17.5/444 – 19/483 w/flange
D 8.5/216
H 3.5/89 – 2U




MBS/PTS Weight (lb/kg)

7.0/3.2


MBS/PTS Mounting

Shelf or 19″ rack mount


MBS/PTS Input Connection

Hardwire Terminal Block


MBS/PTS Output

Connection to Loads

Hardwire Terminal Block


MBS/PTS Output

Connection to UPS

60 foot cable with Anderson PowerPole Pak Connector to UPS


MBS/PTS Cooling

Convection (approx 7 W contractor

coil dissipation)


OUTPUT

Voltage Range, VAC

90 to 150 programmable Default 100 to 130 +/- 2VAC


Frequency, Hz

60 +/- 3 Hz


Maximum Input Current, A

30 A (Resistive)


In Rush Current

Load Dependent


Over Current Protection

Double pole single throw circuit breaker rated 30 A for input and outputDC bus 60 A breaker


Transient Suppression

MOV transient suppression elements (>150 V)


Step Load Response (50% Load Charge)

1/2 Cycle Full Recovery (Full resistive load)


Short Circuit Protection

30 A Circuit Breaker


Battery String Voltage, VDC

48 (Four 12VDC Batteries)


Apparent Power, VA

2000VA (Inverter Mode) 2000VA (Line Mode)


Active Power, W

1500 (Inverter Mode) 1500 (Line Mode)


Power Factor

0.75


Output Voltage, VAC

Line and Buck/Boost

ModeInverter Mode

120 nominal 100-130 +/- 2

VAC (follows input voltage)

120 VAC +/- 5%


Frequency, Hz

60 +/- 0.4 Hz


Transformer

Linear (non-isolated)


Output Waveform

Sine Wave


Output Waveform THD

less than 3% (Resistive Load)


Load Crest Factor

3 : 1(Max)


Overload Capacity

110% for 3 min.

INPUT (ELECTRICAL)

TRAFFIC UPS